Ivica Drazic
engineer | Cg Artist | programmer
 
Home Artwork Structures Low poly Walkthroughs Android Games Tutorials Shops Electronics Contact
 
DSC PC585 / PC1565 alarm system programming


* 8 installer's code (5555/1565 by default) - System light will flash, Armed light turned on, panel is waiting for the 3 digit programming section number.
001 01 04 04 11 # - four zones in this example: delay, 2 interior and 24 hours burglary or tamper
005 010 000 045 001 # - times: 10s delay, 45s exit delay, bell cut-off 1 minute
006 abcd - put your new installer's code
007 efgh - your new master code
008 ijkl - maintenance code, could be the same as master code
013 enable (turn on) 1 and 3 # - normally closed loops, panel shows all troubles when armed
014 enable 6 # - audible exit with urgency
015 enable 1,2,5,6 # - fire keys, audible panic keys, code required for bypassing and master code not changeable
016 enable 1,5,7 # - AC trouble, keypad backlight and bypass status
020 05 # - zone 5 assigned to keypad
160 010 - max. 10 dialing attempts to each telephone number
202 turn on 1,2,3,4,5 # - enable zones
301 first telephone number
303 third telephone number
310 xyzw - alarm center first/third telephone number account code
311 xyzw - same code, alarm center second telephone number account code
329 11 *1*7 02 # - keypad alarms: fire alarm, auxiliary alarm and panic alarm
360 03 # - DTMF Contact ID communicator format
370 000 000 000 000 030 000 007 000 000 000 - 30min AC failure communication delay, 7 days test transmission cycle
371 2355 - test transmission time, for example 23:55
380 enable 1,4,5 # - communication, pulse dialing after 5th attempt, 3rd telephone number
381 turn on 4 # - closing confirmation
401 turn on 1 # - double call enabled
403 ghij - downloading access code, for example: 5898
404 bdfh - panel id code, 5864
406 010 - 10 rings to answer on
701 enable 1 # - 50Hz AC power
702 dissable all #
703 001 - 1s delay between dialing attempts
# - exit
* 6 master code 1 HHMMMMDDYY - time and date, hour, minute, month, day and year
#
* 5 master code 01 abcd 02 rtzj 03 sdfg... # - abcd etc. are access codes
#
For mobile phones:
302 098 *5* xyzrtkjd - second telephone number, 098 T-com Croatia
360 03 06 # - ID contact and residential dial
361 enable 2 also # - 2nd telephone number
FOR 1565 EXTRA:
201 turn on 1 # - partition 2 enabled
202 turn on 1,2,3,4 # - enabling zones in partition 1, example
206 turn on 5,6,7,8 # - enabling zones in partition 2, example
Partitions and keypads:
* 8 installer's code 000 0 11 # - keypad 1 on partition 1 (11-18)
* 8 installer's code 000 0 23 # - keypad 2 on partition 2 (22-28)
Partitions and access codes:
* 5 master code 9 01 1 # 01 access code # - access code 01 in partition 1
* 5 master code 9 02 2 # 02 access code # - access code 02 in partition 2
* 5 master code 03 access code # - access code 03 that works in both partitions

         
DSC NEO HS2016 / HS2032 + TL280(R)E Internet Alarm Communicator


* 8 installer's code (5555 by default) - panel is waiting for the 3 digit programming section number
001 001 003 042 000 # - four zones in this example: delay, instant, 24-hour holdup and null
002 Zone Attributes - enable Bell Audible & Force Arm for Zone 1 or other
005 System Times - in Partition 1 (001) set Entry and Exit Delay, in System Area (000) set Bell Cutoff (4 min default)
006 abcd - put your new installer's code, master code change is disabled here!
009 PGM2 101 Fire & Burglary
201 enable partition zones (Y/N)
301 Phone Number #1 - DFFFFFFFF... Phone Number #2 - 091/xxx... (alarm center)
310 xyzw - System Account Code and Partition 1 Account Code
311 What to send? Partition 1: Alarm/Restore Y, Open/Close Y, Tamper/Restore Y
350 Contact ID communicator format
377 Test Tx Cycle - test transmission time, for example 2355 (23:55)
380 enable(Y) Communications, Alternate Call and Parallel Call
For TL280:
300 001 - 02 for Alt Comm Auto Routing, Receiver #1: Alt Com Auto, Receiver #2: Phone Line
382 Alternate Communicator Enable (5)
384 2-Backup Options - Receiver 2
851 Alternate Communicator Programming subsections:
 001 IP adress
 002 mask
 003 gateway
 004 0087h (Don't let go in!?)
 005 enable 1 2 3 6 8
 006 Receiver Enabled (1)
 021 Account Code (4593FF for example)
 101 Account Code (0000004593 for example)
 103 alarm center IP adress
999 55 accept & reset
# - exit
* 5 master code (4444 default) User 1 (master), User 2 (users) etc. (* erase users)
#

DSC PC1616 / PC1832 / PC1864 alarm system programming


* 8 installer's code (5555 by default, 1234 default master) - panel is waiting for the 3 digit programming section number.
001 01 03 12 00 # - four zones in this example: delay, instant, 24-hr Holdup and null (not used)
005 01 030 045 030 # - Partition 1 System Times: 30s delay 1, 45s delay 2, 30s exit delay
005 09 002 - 2 minutes Bell Cut-Off Timer
006 abcd - put your new installer's code
009 01 01 (Burglary and FireBell Output) PGM1 and PGM2
013 enable 2 for DEOL resistors
104 5 Force Attribute for zone 4, example
202 turn on/off 1,2,3,4,5 # - enable & disable zones
301 first telephone number
303 third telephone number
310 xyzw - Account Code, account + FF, for example: 8251*66
311 xyzw - same Account Code
350 03 03 Contact ID format, 04 for SIA
367 enable 1 and 5 - 1st Telephone Number and Alt Comm
377 003 003 003 000 030 002 001 030 007 030 000 - all default except Test Transmission Cycle (1 day)
378 2355 - test transmission time, for example 23:55
380 enable 5 and 6 - 3rd Telephone Number and Alternate Dial
401 turn on 1 - Answering Machine/Double Call enabled
# - exit
* 6 master code 01 HHMMMMDDYY # - time and date, hour, minute, month, day and year
* 8 installer code * 076 enable 3 # - for 24-hour time format
* 5 master code 01 abcd 02 rtzj... 40 (new master code) sdfg # - abcd etc. are access codes

Choppers

Choppers.pdf (2.9 MB)
PIC18F2550 microcontroller system

MPLAB IDE v.8.89 (110 MB)

C18-MPLAB compiler v.3.46 (80 MB)

PIC18F2550 system programming software: Bolt-amd64-1.0.2.exe (Windows 8)

PIC18F2550 system programming software: Bolt-amd64-1.0.1.exe (Windows 7, 64 bits)

PIC18F2550 system programming software: Bolt-x86-1.0.1.exe (Windows 7, 32 bits, Vista, XP)

System templates, documents, projects and test programs